Skip to main content

Table 1 Evaluation of the presented metrics (in short: (a) Power over HC in kW, (b) Percentage resolved over LC, (c) Unresolved power at top HC in kW) to the first large-scale example when using either a strict hierarchical CES or one with LCs by applying different control strategies

From: Simulation of a Cellular Energy System including hierarchies and neighborhoods

 

Strategy

(a)

(b)

(c)

Import

Export

Import

Export

Only HCs

Greedy

5.273

/

/

2.894

4.858

Equal Request v1

5.204

/

/

2.902

4.885

Equal Request v2

5.231

/

/

3.596

6.267

Equal SoC

5.268

/

/

3.241

6.435

HCs and LCs

Greedy

3.477

0.576

0.584

3.095

5.098

Equal Request v1

3.430

0.580

0.545

3.005

4.955

Equal Request v2

5.457

0.582

0.624

3.181

5.556

Equal SoC

6.038

0.608

0.617

3.135

5.398