Skip to main content

Advertisement

Table 3 Overview of model parameters

From: Modeling flexibility using artificial neural networks

  Description Detail
Electrical demand Winter 15.7 kWh/day
  Intermediate 13.9 kWh/day
  Summer 12.5 kWh/day
Thermal demand Winter 59.9 kWh/day
  Intermediate 46.9 kWh/day
  Summer 18.6 kWh/day
BESS Power [−2.75,2.75] kW
  Usable capacity 2.75 kWh
  Efficiency ηB 0.92
CHP Power el. 0 kW or 2.75 kW
  Power thermal 0 kW or 6.875 kW
Hot water tank Capacity ~17.45 kWh
  750 L at 60 -80 C & 20 C environment
  Efficiency is border of classes B & C (European Union 2013)