Skip to main content

Advertisement

Table 1 Analysis results with an attacker positioned on the Internet

From: Load balancing of renewable energy: a cyber security analysis

Scenarios 1st & 2nd RTUs DER RTU SCADA servers
Model variant A (no DMZ / less secure) 29 days 30 days 27 days
Model variant B (no DMZ / more secure) 66 days 65 days 59 days
Model variant C (DMZ / less secure) 74 days 77 days 70 days
Model variant D (DMZ / more secure) 132 days 131 days 106 days